[Mk2] [Generic] Relay help

Anything to do with the electrics of the car.

Moderators: IMOC Moderators, IMOC Committee Members

Post Reply
cavegod
Posts: 51
Joined: Thu May 22, 2014 9:07 pm
Location: Yorkshire Dales

[Mk2] [Generic] Relay help

Post by cavegod »

Hi all can somebody test their IGN relay for cotinuity between terminals 1&3 (the outside two in the row of 3)

The bgb says they should have but i dont get continuity nor do i on the other two relays in the frunk fuse box. Just wondering if its an error in the bgb.
Peter Gidden
IMOC Affiliated Trackday Organiser
Posts: 10506
Joined: Tue Jan 25, 2005 9:49 am
Location: South Yorkshire

Re: [Mk2] [Generic] Relay help

Post by Peter Gidden »

Teminals 1 and 3 of the IGN relay are the coil winding in the relay so whilst there will be continuity, there will be a small resitance.
cavegod
Posts: 51
Joined: Thu May 22, 2014 9:07 pm
Location: Yorkshire Dales

Re: [Mk2] [Generic] Relay help

Post by cavegod »

Thanks Pete, whilst i don't get continuity between them the relay does click so the coil must work.

So the only thing left for my batt charge light is the alternator regulator.
Peter Gidden
IMOC Affiliated Trackday Organiser
Posts: 10506
Joined: Tue Jan 25, 2005 9:49 am
Location: South Yorkshire

Re: [Mk2] [Generic] Relay help

Post by Peter Gidden »

If you have 12V at all three alternator plug pins with ignition on, then it'll be your alternator.

Just get an exchange unit.