fans blow hot

Discussion and technical advice the SW20 MR2. 3S-GTE, 3S-GE, 3S-FE etc
Anything and everything to do with maintenance, modifications and electrical is in here for the Mk2.

Moderators: IMOC Moderators, IMOC Committee Members

Post Reply
hjscmh
Posts: 48
Joined: Wed Aug 03, 2016 12:11 am
Location: harrogate

fans blow hot

Post by hjscmh »

Hi all.

I have a weird problem. My fans either blow boiling hot, hot, or warm. When i slide the slider all the way to the left to get cold air it still blows warm. Anyone know what this problem could be?

I have done a search and all i can find is people having the opposite problem lol.
mr2garageswindon
Posts: 282
Joined: Wed Oct 15, 2014 3:02 pm

Re: fans blow hot

Post by mr2garageswindon »

Go to the frunk, remove spare wheel and plastics behind and look at the pipe on the left with the cable operating the valve. Check that the cable operates it fully both ways. Open and closed. Could be the cable isn't closing it fully or the valve is knackered.